Liter meters are essential for measuring dispensed quantities, as professionals require precise, reliable, and robust devices. Meters are suitable for a wide range of applications, including diesel, oil, and food. Our range of flow meters also includes models for critical operating conditions. For example, we offer liter meters for high flow rates and pulse liter meters that display the measured flow rate on remote displays. This solution is particularly advantageous for use in commercial vehicles and construction machinery.
Mechanical meters
Mechanical meters are robust and simple in design. They do not require batteries or any other power supply. This makes them a reliable component for measuring fuel and oil dispensing quantities. Selected models are also available with ATEX classification Group II, Cat. 2GcIIB T=85 C (T6).
Our mechanical meters can be used for a wide variety of media:
- Diesel
- Biodiesel HVO, XTL (GTL/BTL/CTL)
- Biodiesel B8, B100
- Heating oil
- Vegetable oils and mineral oils
- Gasoline, E15
- Kerosene
- Aspen 2/4
- AVGAS100/110L and JET A/A1
K33 + K700 - tried and tested and robust
The tried-and-tested, robust K33 and K700 with straight flow direction impress with their high reliability and high-quality materials.
K90 - patented design and functionality
With its patented design and functionality, the new K90 is the perfect complement to the K33 flow meters. Its 90° flow direction saves space and additional fittings in many applications. The advantages of the K90 are particularly evident in tight installation situations.
With an accuracy of +/- 0.6% in the range of 50-70 l/min, the K90 is unbeatable among mechanical meters.
- Flow rate 20-90 l/min
- High accuracy of +/- 0.8%
(0.6% in the range of 50-70 l/min) - Max. pressure 3.5 bar
- Extended temperature range down to -20°C
Media: Diesel up to B8, HVO, and XTL
K33 and K150 for Biodiesel
The BIO meter series is used for biodiesel content of >8%.
Suitable media:
- Diesel
- Biodiesel HVO, XTL (GTL/BTL/CTL)
- Biodiesel B8, B100
- Heating oil
- Vegetable oils and mineral oils
ATEX - Series
The meters meet the requirements of the ATEX directives for potentially explosive atmospheres (ll 2 llB, T6, according to Directive 99/92/EC).
Suitable fuels:
- Gasoline, E15
- Kerosene
- Aspen 2/4
- AVGAS100/110L and JET A/A1
Digital meters
Digital flow meters are used for modern recording and display of flow rates of a wide variety of liquids. They are compact, lightweight, and offer high measurement accuracy and clarity. Normal measurement deviations are in the range of approximately ± 0.5% to ± 1%, depending on the model.
Modern meters differ in terms of flow range, design, and additional functions (e.g., large display or ATEX approval for potentially explosive areas), but always remain focused on the goal of reliably, easily readable, and reproducibly measuring liquid quantities. They are important components in professional refueling and dispensing systems when it comes to precise quantity control and documentation.
K24
Rotatable, digital display with 5-digit partial value and 6-digit total value
- Flow range 7-120 l/min
- Max. pressure 20 bar
- Accuracy ±1%
- Easy to calibrate
K200
Digital display with 5-digit partial value and 6-digit total value
- Flow range 0.1-2.5 l/min
- Max. pressure 550 bar
- Accuracy ±0.5%
- Low flow losses
- Easy to calibrate
K400
Digital display with 5-digit partial value and 7-digit total value
- Flow range 1-30 l/min
- Max. pressure 70 bar
- Accuracy ±0.5%
- Low flow losses
- Easy to calibrate
K600
Digital display with 5-digit partial value and 8-digit total value.
- Flow range 6-150 l/min
- Max. pressure 70 bar
- Accuracy ±0.5%
- Integrated filter on the suction side
- Low flow losses
- Battery level indicator
- Easy to calibrate
NEXT/2
Digital display with 5-digit partial value and 8-digit total value.
- Flow range 6-60 l/min
- Max. pressure 70 bar
- Accuracy ±0.5%
- Easy to calibrate
Digital Pulse meters
Pulse counters are precise flow meters for measuring liquid volumes in industrial and technical applications. They operate according to the pulse principle: inside the measuring device, mechanical elements such as oval gears generate electrical pulses proportional to the volume of liquid that has flowed, which can be converted directly into an exact volume, e.g., in liters per minute.
These meters are ideal for monitoring and documenting the flow of fuels, lubricants, water, antifreeze, AdBlue®/urea solutions, or other liquids with varying viscosities. Thanks to their robust design, high measuring accuracy, and pulse output capability, Pulser counters are ideal for stationary refueling and transfer systems as well as for process and plant automation.
They can be easily integrated into higher-level systems or remote displays and provide reliable measurement data for process optimization.
K24 Pulser
- Accuracy ±1%
- Inlet/outlet 1" male thread x 1" male thread
- with adapter 1" female thread x 1" female thread
- Media: diesel, heating oil, HVO 100
K200 Pulser
- Accuracy ±0.5%
- Input/output 1/4" female thread
- Max. operating pressure 30 bar
- Body with measuring chamber made of aluminum
- Media: diesel, oil, grease, heating oil, HVO 100
K400 Pulser
- Accuracy ±0.5%
- Inlet/outlet ½" female thread
- Max. operating pressure 70 bar
- Aluminum housing and measuring chamber
- Media: diesel, oil, heating oil, radiator antifreeze, HVO 100
K600 Pulser
- Accuracy ±0.5%
- Input/output ½" female thread flange
- Max. operating pressure 20 bar
- Integrated suction filter
- Media: diesel, biodiesel, oil, heating oil, radiator antifreeze, HVO 100
K700 Pulser
- Accuracy ±0.5%
- Input/output 2" female thread
- Max. operating pressure 20 bar
- Integrated suction filter
- Media: diesel, biodiesel, oil, heating oil, radiator antifreeze, HVO 100
K900 Pulser
With remote display (8-digit total quantity, 5-digit partial quantity) and cable connection.
For viscosities from 2 to max. 5.35 cSt.
- Accuracy ±0.5%
- Inlet/outlet 3" female thread flange
- Max. operating pressure 20 bar
- Housing and measuring chamber made of aluminum. With integrated suction filter
- Pulser with pure contact signal (reed switch), single channel
- Media: diesel, biodiesel, heating oil, HVO100
Remote Display
Display panel for combination with a meter over a distance of up to 15 meters. The large display shows the amount dispensed and the non-resettable total amount. Equipped with user software for calibrating the liter counter. It is available as a simple display device and as a pulse generator.
- Display with 5-digit partial value and 8-digit total value
- Battery charge status indicator and flow indicator
- Adjustable pulse count per liter: 1, 2, 10, 20, 50, 100