Pump certified under ATEX/IECEx directive for product safety in Europe (II 2 G Ex d IIA T4 Gb).

Fully-flanged components: Pump, flow meter and filters can be fitted or replaced without the use of sealing paste, making the connections quick and safe.

Features

  • compact and sturdy construction
  • cast iron body
  • ON/OFF Switch
  • anti-noise filter (electromagnetic compatibility EMC)
  • integrated bypass valve
  • thermal protect switch

Batterie Kit EXGO! 12V ATEX with switch with fuel pump, nozzle and hose

Art. Nr. P225X00
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 32 l/min flow rate max. m³ 1,92 m³/h max. pressure 1,2 bar Inlet/outlet 3/4" ft Material pump housing cast iron Built in by-pass valve Electric motor Voltage (DC) 12 V Nominal power 0,084 kW, Rated current (DC) 10 A rotation max. 1400 min-1 Motor protection (thermal) yes Operating mode S1 continuous duty Anti-noise filter (electromagnetic compatibility EMC) 5 m cable with battery clamps Switch ON/OFF ATEX II 2 G Ex d IIA T4 Gb Equipment/Accessories : - manual nozzle - 2,5 m filling hose ¾“ - 1,5 m suction hose ¾“ - Fittings, Filter Mesh, PTFE-Tape - Ground clamp frame size 280 x 160 x 140 mm weight 9 kg

EX 100 AC 230 V, ATEX Pump for Gasoline, Kerosene, Diesel

EX 100 AC 230 V, ATEX
Art. Nr. P390010
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 100 l/min flow rate max. m³ 6 m³/h max. pressure 2 bar Inlet 11/4" BSP Outlet 1" BSP Material pump housing cast iron With Bypass valve built, non-return valve and pressure relief valve, integrated filter Electric motor Voltage (AC) 230 V, 50 Hz Nominal power 1,035 kW, Rated current (AC) 4,5 A rotation max. 1450 min-1 Motor protection (thermal) yes Operating mode Max. duty cycle on/off 30/60 Anti-noise filter (electromagnetic compatibility EMC) Without cable and plug Switch ON/OFF ATEX II 2 G Ex d IIA T4 Gb frame size 240 x 400 x 350 mm weight 23 kg

EX 140 AC 230 V, ATEX Pump for Gasoline, Kerosene, Diesel

EX 140 AC 230 V, ATEX
Art. Nr. P395010
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 140 l/min flow rate max. m³ 7,2 m³/h max. pressure 2 bar Inlet 11/4" BSP Outlet 1" BSP Material pump housing cast iron With Bypass valve built, non-return valve and pressure relief valve, integrated filter Electric motor Voltage (AC) 230 V, 50 Hz Nominal power 1,15 kW, Rated current (AC) 5 A rotation max. 1450 min-1 Motor protection (thermal) yes Operating mode Max. duty cycle on/off 30/60 Anti-noise filter (electromagnetic compatibility EMC) Without cable and plug Switch ON/OFF ATEX II 2 G Ex d IIA T4 Gb frame size 240 x 400 x 350 mm weight 21 kg

EX 50 AC 230 V, ATEX Pump for Gasoline, Kerosene, Diesel

EX 50 AC 230 V, ATEX
Art. Nr. P37300
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 50 l/min flow rate max. m³ 3 m³/h max. pressure 0,6 bar Inlet/outlet 1" ft flange Material pump housing cast iron With Bypass valve built, non-return valve and pressure relief valve, integrated filter Electric motor Voltage (AC) 230 V, 50-60 Hz Nominal power 0,25 kW, Rated current (AC) 1 A rotation max. 2700 min-1 Motor protection (thermal) yes Operating mode Max. duty cycle on/off 30/30 Anti-noise filter (electromagnetic compatibility EMC) Without cable and plug Switch ON/OFF ATEX II 2 G Ex d IIA T4 Gb frame size 253 x 141 x 172 mm weight 7,5 kg

EX 50 DC 12V ATEX Pump for Gasoline, Kerosene, Diesel

EX 50 DC 12V ATEX
Art. Nr. P37100
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 50 l/min flow rate max. m³ 3 m³/h max. pressure 0,6 bar Inlet/outlet 1" ft flange Material pump housing cast iron Built in by-pass valve, non-return valve and pressure relief valve, integrated filter Electric motor Voltage (DC) 12 V Nominal power 0,25 kW, Rated current (DC) 21 A rotation max. 2700 min-1 Motor protection (thermal) yes Operating mode Max. Duty cycle on/off 30/60 Anti-noise filter (electromagnetic compatibility EMC) Without cable and plug Switch ON/OFF ATEX II 2 G Ex d IIA T4 Gb frame size 253 x 141 x 172 mm weight 7 kg

EX 75 DC 12V ATEX Pump for Gasoline, Kerosene, Diesel

EX 75 DC 12V ATEX
Art. Nr. P38000
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 75 l/min flow rate max. m³ 4,5 m³/h max. pressure 1,1 bar Inlet/outlet 1" ft flange Material pump housing cast iron Built in by-pass valve, non-return valve and pressure relief valve, integrated filter Electric motor Voltage (DC) 12 V Nominal power 0,24 kW, Rated current (DC) 20 A rotation max. 2700 min-1 Motor protection (thermal) yes Operating mode Max. Duty cycle on/off 30/30 Anti-noise filter (electromagnetic compatibility EMC) Without cable and plug Switch ON/OFF ATEX II 2 G Ex db IIB T4 Gb frame size 350 x 185 x 260 mm weight 8 kg

EX GO 12V ATEX Pump for Gasoline, Kerosene, Diesel

EX GO 12V ATEX
Art. Nr. P38150
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 32 l/min flow rate max. m³ 1,92 m³/h max. pressure 1,2 bar Inlet/outlet 3/4" ft Material pump housing cast iron Built in by-pass valve Electric motor Voltage (DC) 12 V Nominal power 0,084 kW, Rated current (DC) 10 A rotation max. 1400 min-1 Motor protection (thermal) yes Operating mode S1 continuous duty Anti-noise filter (electromagnetic compatibility EMC) with 3 m cable ATEX II 2 G Ex d IIA T4 Gb frame size 280 x 160 x 140 mm weight 4,2 kg

EX GO 12V ATEX with switch Pump for Gasoline, Kerosene, Diesel

EX GO 12V ATEX with switch
Art. Nr. P38102
Pump for Gasoline, Kerosene, Diesel flow rate max. litres 32 l/min flow rate max. m³ 1,92 m³/h max. pressure 1,2 bar Inlet/outlet 3/4" ft Material pump housing cast iron Built in by-pass valve Electric motor Voltage (DC) 12 V Nominal power 0,084 kW, Rated current (DC) 10 A rotation max. 1400 min-1 Motor protection (thermal) yes Operating mode S1 continuous duty Anti-noise filter (electromagnetic compatibility EMC) with 5 m cable Switch ON/OFF ATEX II 2 G Ex d IIA T4 Gb frame size 280 x 160 x 140 mm weight 5,5 kg